July 28, 2012

4L60-E: No Move After Rebuild

Ed Lee

A 2006 Chevrolet Suburban C1500 was brought to atransmissionshop. The vehicle was equipped with a 5.3L V8 gas engine and a4L60-Etransmission. The customer complaint was “slipping in reverse.” The vehicle had 128,967 miles on the odometer, so the customer was sold a complete rebuild, including a rebuilt torque converter. The rebuild procedure and the R & R seemed to go routinely until cooler flow was being checked. The R & R man reported that there was no cooler flow and no engagement when the shifter was moved to any drive range, including reverse. The cooler line was then disconnected, ahead of the cooler, and this verified that no flow was coming out of the transmission. At that point, the “blame game” began.

传输rebuilder accused the R & R man of breaking the pump during the installation process. The R & R man was certain that he had done his job correctly, and that the rebuilder must have done something wrong during the rebuild. To help pinpoint the problem, a pressure gauge was installed into the line pressure port. To everyone’s surprise, the line pressure was normal. This meant that not only was the pump not broken, but the PR valve also was not stuck open. This also meant that the transmission would have to be removed from the vehicle and at least partially disassembled. The rebuilder came to the conclusion that there was a restriction in the charge oil passage. A check of the transmission build sheet showed that the reverse drum and the stator support had been replaced during the rebuild process.

Armed with this information and some other details supplied by the converter rebuilder (no oil had entered the converter), the stator support seemed like the logical place to start looking for the charge oil blockage. This proved to be a good choice because the charge oil port in the replacement stator support did not align with the charge oil passage in the pump cover.


Figure 1:
Early Design (77918S-1K)
Figure 2:
Feed Hole Moved for ISS (77918S-09K)


InFigures 1&2以上,右边是通过冷却器return/lube passage. This passage has remained in the same relative position throughout the life of the 4L60/65/70-E transmissions. The next passage to the left is the charge oil/TCC release passage. This passage was moved to make room for the input speed sensor (ISS).

The rebuilder could see that there was no hole for the sensor in his cover and reasoned that his non-ISS cover required the early-style, non-ISS stator support.Figure 3shows a cover with the ISS hole.

Figure 3:
Cover with Sensor Hole
Figure 4:
Transition Pump


What the rebuilder did not realize is that the pump changes which led up to the sensor style seen inFigure 3took place in steps for more than a year. The first pump change step included a relocation of the converter charge/TCC release oil feed hole. The cover shown inFigure 4clearly does not have the sensor hole, but the boss is already in place for the future development and eventual drilling of the hole. The converter feed hole is in the late-style location and it requires an ISS-style stator support.

Another way to identify a pump that requires the late-style support is to look for the short boost valve assembly bore as seen inFigure 5. Early-style boost bores reached all the way out to the pump’s outer diameter.


Figure 5:
Short Boost Valve Assembly Bore


In 2010, ATSG did a great seven-page bulletin on the transition from the non-ISS transmissions to the transmissions equipped with an ISS. Following this bulletin’s information would have prevented this problem. The transition from non-ISS to transmissions equipped with an ISS took more than a year on some models (February 2005 to early 2006). Exercise caution when rebuilding any of the affected units.

Ed Lee is a Sonnax Technical Specialist who writes on issues of interest to torque converter rebuilders. Sonnax supports theTorque Converter Rebuilders Association.

Related Units


Related Parts

While Sonnax makes every effort to ensure the accuracy of technical articles at time of publication, we assume no liability for inaccuracies or for information which may become outdated or obsolete over time.