January 16, 2014
The continuous oscillation of the secondary pressure regulator valve in Toyota/Lexus A750, A760, A960 and AB60 series units wears the valve spools and valve body bore at the contacting surfaces. This wear results in TCC pressure irregularities and valve instability. If pressure is high, harsh lockup clutch engagement can result. If the pressure is too low, the TC clutch cannot achieve complete lockup. Continuous clutch slippage will lead to burnt clutch material and converter. Under these conditions, loss of mileage and poor drivability are to be expected.
Sonnax oversized secondary pressure regulator kit 147741-10K includes a high-quality steel valve with annular grooves to reduce side load wear and extend valve and valve body life. Sonnax tool kitF-147741-TL4was designed as a multipurpose tool. Used in conjunction with ourVB-FIXreaming fixture, both the main pressure regulator bore and the secondary pressure regulator bore can be reamed and prepared for their respective kits: 147741-10K and oversized pressure regulator and boost valve kit147741-04K.
Sonnax valve body layouts provide a detailed overview of individual units making it quick and easy to determine what’s available for the specific valve body you’re working on.See all Sonnax valve body layouts.
January 16, 2014
December 03, 2013
September 30, 2005
Gregg Nader
March 26, 2019
Jim Dial
Vacuum testing at the port(s) indicated fails to hold the recommended minimum in-Hg, or if wear is visually detected.