December 09, 2013
丰田和雷克萨斯U660E, U660F, U760E and U760F transmissions may exhibit 3-4 shift flares, slipping in 4-5-6, and burnt C2 clutches due to wear in the C2 apply control bore. Sonnax oversized C2 apply control valve kit 47740-63K restores the necessary hydraulic clearances required for proper valve function.
December 09, 2013
December 30, 2013
October 26, 2017
Vacuum testing at the port(s) indicated fails to hold the recommended minimum in-Hg, or if wear is visually detected.